SPIND SF Side Flow Floor Gully/Trap
Fully Embedded Into Concrete Slab
SPIND Side Flow Floor traps are integral part of all buildings in their usage as a waste water discharge system that will trap dirt from entering the SWV pipe and at the same time providing a trap seal to prevent foul gases, rodents and insects from entering back into buildings. SIRIM BS EN 1253K3 Standards (SIRIM Certificate No.PS112002)
Conventional floor traps usage in our current situation warrants us to clean or dislodge any blockage in trap from the floor below, which will cause inconvenience and its messy installation will deprive head room in toilets.
Spind is proud to present our fully cast in slab design trap that will overcome all these drawbacks and can be easily accessed and cleaned from the top.
Our design allows the basin or kitchen sink to be connected directly to trap. The trap itself has a 2″ outlet that is more than sufficient to allow for flow rates in bathrooms.

SPIND SF Side Flow Floor Gully/Trap
Fully Embedded Into Concrete Slab
SPIND Side Flow Floor traps are integral part of all buildings in their usage as a waste water discharge system that will trap dirt from entering the SWV pipe and at the same time providing a trap seal to prevent foul gases, rodents and insects from entering back into buildings. SIRIM BS EN 1253K3 Standards (SIRIM Certificate No.PS112002)
Conventional floor traps usage in our current situation warrants us to clean or dislodge any blockage in trap from the floor below, which will cause inconvenience and its messy installation will deprive head room in toilets.
Spind is proud to present our fully cast in slab design trap that will overcome all these drawbacks and can be easily accessed and cleaned from the top.
Our design allows the basin or kitchen sink to be connected directly to trap. The trap itself has a 2″ outlet that is more than sufficient to allow for flow rates in bathrooms.

Connection of Air-condition drain pipe must be connected by using SPIND Special Design 20mm U-Bend with Bush. Dischange of Air-Condition drain pipe into floor trap may cause condensation on the floor trap base or on pipe leading to stack. Proper insulation with use of insuflex is recommended to prevent this problem.


Connection of Air-condition drain pipe must be connected by using SPIND Special Design 20mm U-Bend with Bush. Dischange of Air-Condition drain pipe into floor trap may cause condensation on the floor trap base or on pipe leading to stack. Proper insulation with use of insuflex is recommended to prevent this problem.

Grating Option







SPIND 6 SP-STH001 Squaretile (150mm x 150mm)


















INFO
SPIND MALAYSIA SDN BHD
38, Jalan Utama 1/2,
Taman Perindustrian Puchong Utama Sekysen 1,
47130 Puchong,
Selangor.
Tel: 603 8060 5500
Fax: 603 8060 5511
Email: info@spind.com.my
Sales Inquiry:
+6012-249 9821 (Mr. Ngai)
+6019-282 0972 (Mr. Cheong)
PRODUCTS & SERVICES
CONTACT US
PRODUCTS & SERVICES
CONTACT US